Fin Fan Cooler Heat Exchanger
Fin fan cooler heat exchanger is a heat exchanger that uses air as the cooling medium. Its design utilizes finned tubes to increase the heat transfer surface area, resulting in a more compact structure.
- Common Applications Include:
- Motor and Generator Cooling
Power Substation Transformer Cooling
Petro-Chemical Plants
Power Plants
Reliable & Compact Air Cooled Heat Exchangers
Product Details
A fin fan cooler, also known as an air-cooled heat exchanger (ACHE), uses large fans to force ambient air across finned tubes, transferring heat from the hot process fluid inside the tubes to the air, thereby cooling or condensing the fluid.
A Fin Fan Cooler Heat Exchanger is a heat exchanger that uses air as the cooling medium. Its design utilizes finned tubes to increase the heat transfer surface area, resulting in a more compact structure. Unlike cooling towers that require a coolant, finned air coolers utilize natural air to cool the process fluid. This not only reduces power consumption but also minimizes corrosion problems and lowers maintenance costs.
Working Principle
Fluid Flow: Hot fluid (oil, water, gas) enters the tubes within the tube bundle.
Air Flow: Fans (forced draft or induced draft) blow or draw cool ambient air across the outside of the tubes.
Heat Transfer: Fins attached to the tubes significantly increase the surface area, allowing the hot fluid to efficiently transfer heat to the cooler air.
Result: The fluid is cooled (or condensed), and the heated air is discharged from the equipment. This type of equipment is commonly used in large-scale cooling applications where water is not suitable.
Main Components and Features
Finned Tubes: Tubes with fins (aluminum, steel) to maximize heat transfer surface area, thus reducing the number of tubes required.
Fans: Axial fans provide forced draft (pushing air in) or induced draft (drawing air out).
Tube Bundle: Arranged horizontally, vertically, or at an angle, made of materials such as carbon steel, stainless steel, or copper.
We know these applications can be demanding, that is why we take quality seriously. For the pasts 20 years, our experienced thermal engineers have worked to design reliable and compact heat exchangers, that are capable of functioning in even the most strenuous high pressure, high temperature, and corrosive environments.
When you choose Datang, you choose safe temperature regulation and quality Air Cooled Heat Exchangers guaranteed to meet or exceed your performance requirements.
Fin Bonding Types

Service Center & Aftermarket
Full service and aftermarket capability for all Datang Finned Tube owned brands. Dedicated to keeping you online and productive. We respond to your needs promptly and efficiently. One-stop shop for all replacement units and parts.
Contact Us
If you are looking to save money by maximizing your heat transfer efficiency, then you came to the right place. Datang is your premier supplier for heat exchanger manufacture, design, and repair. For more information about our air cooled heat exchanger capabilities, send us an email at info@datangpipe.com. Or speak with a thermal design engineer directly, by giving us a call at +86 15690122018(Whatsapp).
A: Fin fan cooler heat exchanger can be customized. We can produce it according to your drawings, and we can sign a confidentiality agreement for your patented products. For more information, please contact us.
A: Always a pre-production sample,before mass production;always final inspection before shipment.
Inspection & Guarantee Certificate is supplied with shipment, and the Third Party Inspection is available.
A: One year after shipping.
A: We have workshop can supply all parts of the air cooled heat exchanger, and 90% of spare parts can be distributed to any
place in the world within one week!
A: We can arrange for experienced engineers to provide online video guidance on product installation and train your staff on equipment operation and maintenance.
A: Datang provides factory inspection videos, and production progress will be sent to you via pictures and videos, allowing you to feel as if you are on-site.
A: Email: info@datangpipe.com
Whatsapp & Wechat: +86 15690122018
- Datasheet
- Drawing
- Certificates
|
Part Models
|
Tubes QTY
|
Pressure
(MPa) |
Tube bank
QTY |
Bare tube heat transfer area(m2)
|
Finned tube heat transfer area(m2)
|
|
GP12x3-4-172-1.6S-23.4/L(DR)-Ia
|
182
|
1.6
|
4 |
172
|
4025
|
|
GP12x3-4-172-2.5S-23.4/L(DR)-Ia
|
2.5
|
||||
|
GP12x3-4-172-4.0S-23.4/L(DR)-Ia
|
4.0
|
||||
|
GP12x3-8-344-4.0S-23.4/L(DR)-Ia
|
364
|
4.0
|
8
|
344
|
8050
|
|
GP9x2-6-126-1.6S-23.4/L(DR)-Ia
|
177
|
1.6
|
6
|
126
|
2948
|
|
GP6x1-8-52.2-4.0S-23.4/L(DR)-Ia
|
108
|
4.0
|
8
|
52.2
|
1221
|



Induced Type Fin Fan Cooler Heat Exchanger
An Induced Type Fin Fan Cooler Heat Exchanger pulls ambient air through finned tubes using fans mounted above the tube bundle, cooling process fluids by exposing them to air for efficient heat dissipation, ideal where water is scarce, offering uniform air distribution, protection from elements, and lower recirculation compared to forced draft designs, commonly used in oil, gas, and power industries.
Forced Type Fin Fan Cooler Heat Exchanger
A Forced Type Fin Fan Cooler is an air-cooled heat exchanger (ACHE) that uses fans to push ambient air across finned tubes, forcing heat from a hot process fluid (liquid/gas) to the air, cooling it for industrial processes, common in petrochemicals, power, and gas processing where water is scarce, offering efficient heat transfer via increased surface area from fins with benefits like lower operating costs and easier fan maintenance.


About Datang Fin Fan Cooler in Power Plant
Datang’s fin fan cooler in power plant adopts a finned tube design, replacing traditional water cooling with air cooling, significantly reducing water consumption in power plants and achieving outstanding energy-saving effects. Its forced air cooling system is adaptable to water-scarce environments, has high heat dissipation efficiency, and is easy to maintain. The advantages of the fin fan cooler in power plant include: energy and water conservation, compact structure, stable operation, and meeting stringent environmental protection requirements.
Datang provides comprehensive after-sales service, including rapid fault response and customized maintenance solutions, ensuring long-term efficient operation of the equipment. Datang provides worry-free support to customers with a professional team and localized services, improving overall operational reliability.
ODM / OEM Fin Fan Cooler Finned Tube Air Cooler Heat Exchanger
Meticulously crafted, our radiators are fortified with resilient copper brazing, ensuring longevity and robust performance.
Our dimensions are expertly tailored to meet OEM specifications, guaranteeing a flawless fit with every installation.


Fin Fan Cooler Finned Tube Air Cooler Heat Exchanger Package
Datang fin fan coolers are meticulously encased in robust, high-quality wooden cases, perfectly designed to withstand a multitude of shipping methods, be it by sea, rail, or expedited courier services. You can have complete confidence that your product will be delivered in pristine condition, safeguarded against any potential transit damage.