Fin Fan Cooler in Power Plant
Fin Fan Coolers (finned tube air coolers heat exchanger) are primarily used in power plants for efficient heat dissipation, especially in scenarios with water shortages or stringent environmental requirements, replacing traditional water-cooling systems.
- Base Tube Material:
Carbon steel,Stainless steel - Fin Material:Copper,Aluminum
Product Details
Fin Fan Cooler Technology Principle
Fin Fan Coolers use a fan to force air through finned tube bundles, achieving cooling through heat exchange between the air and the working fluid (such as steam or coolant) inside the tubes. Some designs employ V-shaped or flat-plate structures to optimize heat dissipation area.
Fin Fan Cooler Energy Saving and Water Saving
Direct air-cooled systems (such as the Matimba power plant in South Africa) can reduce water consumption to 0.1 L/kWh, only 1/19th that of wet-cooled power plants. For example, a 4000MW power plant saves approximately 46.5 million cubic meters of water annually.
Fin Fan Cooler Application Cases
Thermal Power Generation: Reducing flue gas temperature (e.g., from 180℃ to 120℃), recovering 500,000 GJ of heat annually.
Cryptocurrency Mining Farms: Utilize dry coolers to directly cool servers, combined with plate heat exchangers to isolate the heat source.
Fin Fan Cooler Customization Needs
Suppliers offer models with different heat dissipation capacities (40kW-240kW) and materials (stainless steel/aluminum), supporting variable frequency control to adapt to load changes.
Fin Fan Cooler Daily Maintenance Points
1. Temperature and Noise Monitoring
Check exhaust temperature (≤100℃) and oil temperature (≤85℃) daily. Listen for smooth fan operation; immediately stop the machine and investigate if abnormal noise or high temperature is detected.
2. Fin Fan Cooler Surface Cleaning
Blow away dust weekly with compressed air (pressure ≤0.5MPa) along the fin direction. For heavy oil stains, rinse with a neutral detergent at low pressure to prevent fin collapse.
3. Regular Deep Maintenance of the Fin Fan Cooler
Condenser Cleaning
After power outages quarterly, use a soft brush or specialized cleaning agent to remove stubborn dirt from the fins. Thoroughly dry after chemical cleaning.
Fan System Inspection
Monthly check the motor bearing lubrication, fan blades for cracks, and belt tension. Replace worn parts as necessary.
4. Key Precautions for Fin Fan Coolers
Safe Operation: Power must be disconnected and pressure released before cleaning to avoid damaging the fins with high-pressure water or strong acids/alkalis.
Environmental Requirements: Ensure good ventilation around the unit to prevent dust accumulation that could affect heat dissipation efficiency.
- Datasheet
- Drawing
- Certificates
|
Part Models
|
Tubes QTY
|
Pressure
(MPa) |
Tube bank
QTY |
Bare tube heat transfer area(m2)
|
Finned tube heat transfer area(m2)
|
|
GP12x3-4-172-1.6S-23.4/L(DR)-Ia
|
182
|
1.6
|
4 |
172
|
4025
|
|
GP12x3-4-172-2.5S-23.4/L(DR)-Ia
|
2.5
|
||||
|
GP12x3-4-172-4.0S-23.4/L(DR)-Ia
|
4.0
|
||||
|
GP12x3-8-344-4.0S-23.4/L(DR)-Ia
|
364
|
4.0
|
8
|
344
|
8050
|
|
GP9x2-6-126-1.6S-23.4/L(DR)-Ia
|
177
|
1.6
|
6
|
126
|
2948
|
|
GP6x1-8-52.2-4.0S-23.4/L(DR)-Ia
|
108
|
4.0
|
8
|
52.2
|
1221
|



About Datang Fin Fan Cooler in Power Plant
Datang’s fin fan cooler in power plant adopts a finned tube design, replacing traditional water cooling with air cooling, significantly reducing water consumption in power plants and achieving outstanding energy-saving effects. Its forced air cooling system is adaptable to water-scarce environments, has high heat dissipation efficiency, and is easy to maintain. The advantages of the fin fan cooler in power plant include: energy and water conservation, compact structure, stable operation, and meeting stringent environmental protection requirements.
Datang provides comprehensive after-sales service, including rapid fault response and customized maintenance solutions, ensuring long-term efficient operation of the equipment. Datang provides worry-free support to customers with a professional team and localized services, improving overall operational reliability.
ODM / OEM Fin Fan Cooler Finned Tube Air Cooler Heat Exchanger
Meticulously crafted, our radiators are fortified with resilient copper brazing, ensuring longevity and robust performance.
Our dimensions are expertly tailored to meet OEM specifications, guaranteeing a flawless fit with every installation.


Fin Fan Cooler Finned Tube Air Cooler Heat Exchanger Package
Datang fin fan coolers are meticulously encased in robust, high-quality wooden cases, perfectly designed to withstand a multitude of shipping methods, be it by sea, rail, or expedited courier services. You can have complete confidence that your product will be delivered in pristine condition, safeguarded against any potential transit damage.














